Question
Why does my Mini Timer flash "18:88"?
Answer
The MT10A and MT522 Mini Timers can manually control 8 modules and can be programmed to automatically control 4 modules. You can set 2 ON times and 2 OFF times for each of these 4 modules.
If you try to program more than 2 on or off times for a module, the display will flash "18:88" to let you know you exceeded the limit.
To clear this, set the slide switch to REVIEW, press the number button that you pressed when the display changed to 18:88, and then press CLEAR. Or, simply unplug the Mini Timer and take the battery out; then plug it back in and reset the time and your programmed events.
Note: You can only program times for units 1-4 or 5-8 (not both). If you set times for units 1-4 and then move the slide switch to position 5-8, the times you set for units 1-4 will affect modules set to 5-8 instead. If you try to program more times for units 5-8, the display will show 18:88 as described above, indicating that you have exceeded the 2 on/off times allowed per unit.