Powerflash
Revision as of 21:02, 21 April 2014 by X10douglas (talk | contribs)
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
X10 PF284 and PRO PSC01: Powerflash Module
Error creating thumbnail: /bin/bash: /usr/bin/convert: No such file or directory Error code: 127
The Powerflash Module is different from most other X10 modules in that it sends X10 codes rather than receiving them. It can be triggered by a dry contact closure or a low voltage input (6-18 volts AC, DC, or audio). When connected to the output of a burglar alarm system or alarm panel, it can flood your house with light when the alarm is tripped.
This device can be activated by a magnetic window switch, photo cell, moisture sensor, motion detector, pressure switch or anything that gives a switch closure. Applications for this versatile interface are limited only by your imagination. It can trip lights directly or activate sophisticated macros in ActiveHome Pro.
Questions
How do I set up my Powerflash module?
Specifications
- Weight
- 0.32 lbs.
- Power Supply
- 120VAC @ 60Hz
- Power
- 2W
- Terminal Voltage
- 1V min, 18V max
- Input Switch Position A
- 1 - 18VDC
- Input Switch Position B
- Dry Contact Closure