http://graphics.x10.com/images/pf284_blue.GIF
+
'''X10 PF284 and PRO PSC01: Powerflash Module'''
 +
[[File:psc01_500.jpg|right|psc01|link=]]
  
[[Image:Pf284.jpg|thumb]]
 
  
Model: PF284
+
The Powerflash Module is different from most other X10 modules in that it sends X10 codes rather than receiving them. It can be triggered by a dry contact closure or a low voltage input (6-18 volts AC, DC, or audio). When connected to the output of a burglar alarm system or alarm panel, it can flood your house with light when the alarm is tripped.
 +
 
  
The PSC01 Powerflash Module is different from most other X10 modules - it sends X10 codes rather than receiving them. It can be triggered by a dry contact closure or a low voltage input (6-18 volts AC, DC, or audio). When connected to the output of a burglar alarm system or alarm panel, it can flood your house with light when the alarm is tripped.
 
 
This device can be activated by a magnetic window switch, photo cell, moisture sensor, motion detector, pressure switch or anything that gives a switch closure. Applications for this versatile interface are limited only by your imagination. It can trip lights directly or activate sophisticated macros in [[ActiveHome Pro]].
 
This device can be activated by a magnetic window switch, photo cell, moisture sensor, motion detector, pressure switch or anything that gives a switch closure. Applications for this versatile interface are limited only by your imagination. It can trip lights directly or activate sophisticated macros in [[ActiveHome Pro]].
  
==Product Pages==
 
  
[http://www.x10.com/security/x10_pf284.htm Purchase]
+
*[http://www.authinx.com/manuals/X10/PF284.pdf Detailed PF284 Instructions]
 +
*[http://www.authinx.com/manuals/X10/PSC01.pdf Detailed PSC01 Instructions]
 +
*[http://www.x10.com/psc01-powerflash-burgular-alarm-interface.html Purchase '''PSC01''']
 +
*[http://www.x10community.com/forums/index.php?board=7.0 Forums]
 +
*[https://www.youtube.com/watch?v=6jR3oNzlf7o&feature=youtu.be '''Setup Video''']
 +
 
  
[http://www.x10community.com/forums/index.php?board=7.0 Forums]
 
  
 
==Questions==
 
==Questions==
 
[[Powerflash Setup|How do I set up my Powerflash module?]]
 
[[Powerflash Setup|How do I set up my Powerflash module?]]
 +
 +
  
 
== Specifications  ==
 
== Specifications  ==
Line 22: Line 27:
 
;Power Supply:  120VAC @ 60Hz   
 
;Power Supply:  120VAC @ 60Hz   
 
;Power:  2W   
 
;Power:  2W   
;Terminal Voltage:  6V min, 18V max   
+
;Terminal Voltage:  1V min, 18V max   
;Input Switch Position A: 6 - 18VDC
+
;Input Switch Position A: 1 - 18VDC
 
;Input Switch Position B: Dry Contact Closure
 
;Input Switch Position B: Dry Contact Closure
 +
 +
  
 
==Related Products==
 
==Related Products==
Line 35: Line 42:
 
[[Security Systems]]
 
[[Security Systems]]
  
[[Category: Product Information]]
+
 
 +
 
 +
[[category: Configuration]]
 +
[[category: Hardware]]
 +
[[category: Product Information]]
 +
[[category: Specifications]]

Latest revision as of 20:05, 24 April 2015

X10 PF284 and PRO PSC01: Powerflash Module

psc01


The Powerflash Module is different from most other X10 modules in that it sends X10 codes rather than receiving them. It can be triggered by a dry contact closure or a low voltage input (6-18 volts AC, DC, or audio). When connected to the output of a burglar alarm system or alarm panel, it can flood your house with light when the alarm is tripped.


This device can be activated by a magnetic window switch, photo cell, moisture sensor, motion detector, pressure switch or anything that gives a switch closure. Applications for this versatile interface are limited only by your imagination. It can trip lights directly or activate sophisticated macros in ActiveHome Pro.



Questions

How do I set up my Powerflash module?


Specifications

Weight
0.32 lbs.
Power Supply
120VAC @ 60Hz
Power
2W
Terminal Voltage
1V min, 18V max
Input Switch Position A
1 - 18VDC
Input Switch Position B
Dry Contact Closure