Difference between revisions of "AirSight Alarm Input Armed /IO Linkage on Alarm"

From X10Wiki
Jump to navigation Jump to search
 
(10 intermediate revisions by the same user not shown)
Line 1: Line 1:
== Question ==
+
==Question==
 
How do I setup my Airsight Cameras to use Alarm Input Armed / IO Linkage on Alarm?
 
How do I setup my Airsight Cameras to use Alarm Input Armed / IO Linkage on Alarm?
  
----
 
  
Models XX34A, XX36A, XX41A, XX42A, XX40A
 
  
== Answer ==
+
==Answer==
  
 
If you want to connect external alarm devices, when it’s an alarm input device, choose '''Alarm Input Armed''' to enable it, when it’s an output device, choose '''IO Linkage on Alarm''' to enable it.
 
If you want to connect external alarm devices, when it’s an alarm input device, choose '''Alarm Input Armed''' to enable it, when it’s an output device, choose '''IO Linkage on Alarm''' to enable it.
Line 13: Line 11:
  
  
There are two options for '''Trigger Level'''.
+
===Trigger Level===
 +
 
 +
There are two options for '''Trigger Level'''
  
 
'''High:''' When the external alarm device is close, then the alarm is triggered.
 
'''High:''' When the external alarm device is close, then the alarm is triggered.
Line 21: Line 21:
 
[[Image:ALARMINPUT2.png]]
 
[[Image:ALARMINPUT2.png]]
  
There are two options for '''Output Level'''.
+
 
 +
 
 +
===Output Level===
 +
 
 +
There are two options for '''Output Level'''
  
 
'''High:''' When chosen, the IO Pins work as a switch that is closed.
 
'''High:''' When chosen, the IO Pins work as a switch that is closed.
Line 29: Line 33:
 
[[Image:ALARMINPUT3.png]]
 
[[Image:ALARMINPUT3.png]]
  
'''IO Pins for IO Alarm Linkage'''
+
 
 +
 
 +
 
 +
==IO Pins for IO Alarm Linkage==
  
 
[[Image:ALARMINPUT4.png]]
 
[[Image:ALARMINPUT4.png]]
  
'''I/O PINS: 1 Output 2 Output 3 Alarm input 4 Input (GND)'''
+
'''I/O PINS:'''
'''Input pins:''' The input pins can be used for 1-way external sensor input. For example, you may connect a
+
 
 +
# '''Output'''
 +
# '''Output'''
 +
# '''Alarm Input'''
 +
# '''Input (GND)'''
 +
 
 +
 
 +
'''Output pins:''' Output pins (1 & 2) can be used to enable IO linkage on alarm.
 +
 
 +
* For example, you might connect an external siren to sound when motion is detected.
 +
 
 +
* You can also manually control the output switches via the WebUI buttons [[Image:ALARMINPUT5.png]] & [[Image:ALARMINPUT6.png]] to turn the connected device ON/OFF.
 +
 
 +
 
 +
 
 +
 
 +
'''Input pins:''' Input pins (3 & 4) can be used for 1-way external sensor input to the camera.
  
Passive Infrared (PIR) Sensor to it for motion detection. When the external sensor is triggered, the IP camera
+
* For example, you might connect an external Passive Infrared (PIR) Sensor to it triggered the camera to send an e-mail and/or trigger the siren attached to the Output Pins (above).
  
can be programmed to send an e-mail with a picture or to control the internal relay output.
+
* If you link an external alarm device to Pins 3 and 4, when '''Alarm Input Armed''' is selected, the external alarm is enabled.
  
If you link an external alarm device to Pins 3 and 4, when '''Alarm Input Armed''' is selected (Figure 10.0), the
 
  
external alarm is enabled.
 
  
'''Output pins:''' The output pins can be enable IO linkage on alarm.
+
'''NOTE:''' All pins work as a switch only.
  
You can also use [[Image:ALARMINPUT5.png]] & [[Image:ALARMINPUT6.png]]
 
to control IO output Switch ON/OFF (See Figure 4.4).
 
  
'''NOTE:''' All the pins work as switch only.
 
  
  
 
[[category: Configuration]]
 
[[category: Configuration]]

Latest revision as of 01:52, 8 January 2016

Question

How do I setup my Airsight Cameras to use Alarm Input Armed / IO Linkage on Alarm?


Answer

If you want to connect external alarm devices, when it’s an alarm input device, choose Alarm Input Armed to enable it, when it’s an output device, choose IO Linkage on Alarm to enable it.

ALARMINPUT1.png


Trigger Level

There are two options for Trigger Level

High: When the external alarm device is close, then the alarm is triggered.

Low: When the external alarm device is switching off, then the alarm is triggered.

ALARMINPUT2.png


Output Level

There are two options for Output Level

High: When chosen, the IO Pins work as a switch that is closed.

Low: When chosen, the IO Pins work as a switch that is switching off.

ALARMINPUT3.png



IO Pins for IO Alarm Linkage

ALARMINPUT4.png

I/O PINS:

  1. Output
  2. Output
  3. Alarm Input
  4. Input (GND)


Output pins: Output pins (1 & 2) can be used to enable IO linkage on alarm.

  • For example, you might connect an external siren to sound when motion is detected.
  • You can also manually control the output switches via the WebUI buttons ALARMINPUT5.png & ALARMINPUT6.png to turn the connected device ON/OFF.



Input pins: Input pins (3 & 4) can be used for 1-way external sensor input to the camera.

  • For example, you might connect an external Passive Infrared (PIR) Sensor to it triggered the camera to send an e-mail and/or trigger the siren attached to the Output Pins (above).
  • If you link an external alarm device to Pins 3 and 4, when Alarm Input Armed is selected, the external alarm is enabled.


NOTE: All pins work as a switch only.