Powerflash
X10 PF284 and PRO PSC01: Powerflash Module
The Powerflash Module is different from most other X10 modules in that it sends X10 codes rather than receiving them. It can be triggered by a dry contact closure or a low voltage input (6-18 volts AC, DC, or audio). When connected to the output of a burglar alarm system or alarm panel, it can flood your house with light when the alarm is tripped.
This device can be activated by a magnetic window switch, photo cell, moisture sensor, motion detector, pressure switch or anything that gives a switch closure. Applications for this versatile interface are limited only by your imagination. It can trip lights directly or activate sophisticated macros in ActiveHome Pro.
Questions
How do I set up my Powerflash module?
Specifications
- Weight
- 0.32 lbs.
- Power Supply
- 120VAC @ 60Hz
- Power
- 2W
- Terminal Voltage
- 1V min, 18V max
- Input Switch Position A
- 1 - 18VDC
- Input Switch Position B
- Dry Contact Closure